  • The Dryvex commercial line of dehumidifiers will keep your consruction and restoration projects on schedule and on budget by decreasing drying time and increasing production time for interior finish work. Features include high impact roto-molded housing, lightweight integrated design and greater moisture removal al lower temperature and relative humidity.
  • Low temperature operation to 40 F continues to remove moisture from the air at colder, yet humid conditions.
  • Twin 5 inch rear vents allow the warm, dry, processed air to be vented out or ducted with optional 10" layflat or 2" x 5" sections of ductwork, to aid in drying area.
  • Unit is CSA approved.
  • Features 300 CFM blower to efficiently move more humid air through the system, delivering increased air changes per hour.
  • Low grain refrigerant system removes more moisture from the air than conventional refrigerant systems.
  • Digital hour meter, for recording job times, comes standard with back up battery unit to ensure the meter can be read even if the unit is unplugged.
  • Electronic controls allows for convenient, quick setup and simple operation with no knobs or buttons that can easily be damaged in transport or on the job.
  • Tough roto-molded cabinet withstands the rigors of operation, making this machine extremely rental friendly.
  • Integrated handles, both upper and lower, allow for easy lifting and moving and reduces the need for replacement parts.
  • There is a pump with-in the machine to push out the water to a designated area.
  • Technical data:
  • 115v 60hz
  • Shipping weight (including packaging)= 110
  • Shipping size = 25.5 x 20.5 x38.5
  • Length x width x height=23.5x18x36.75
  • Dry weight=100
  • AC Voltage=115
  • Operational range=33-104
  • Type of coolant=LGR
  • Air Flow=300
  • Dehumidifying performance=115 PINTS
  • Discharge hose is approximately 28'
  • DRYING EQUIPMENT RENTAL GUIDE
  • STEPS TO A DRY STRUCTURE
  • EXTRACT: REMOVE ALL THE LIQUID WATER YOU CAN. THIS MOST EFFECTIVELY DONE WITH A DRI-EAZ FLOOD KING DX OR WET/DRY VACUUMS, PROFESSIONAL CARPET EXTRACTORS, SQUEEGEES AND MOPS. IT IS MUCH FASTER TO REMOVE THE WATER THIS WAY. IF THERE ARE ANY WET ITEMS THAT ARE DAMAGE, NOW IS THE TIME TO REMOVE THEM.
  • GRADE THE LOSS:
  • -A BASIC LOSS THAT IS SMALL OR HAS MOSTLY DENSE WET MATERIALS LIKE WOOD OR CONCRETE
  • -A COMPLEX LOSS THAT HAS WET DENSE AND WET SOFT MATERIALS LIKE CARPET AND WALLS DETERMINE HOW MANY DRI-EAZ AIRMOVERS ARE NEEDED FOR YOUR LOSS:
  • -ADD UP THE SQUARE FOOTAGE OF THE AREA THAT IS WET.
  • -A BASIC LOSS NEEDS A DRI-EAZ AIRMOVER EVERY 200 SQUARE FEET. BE SURE TO HAVE AT LEAST ONE PER AREA/
  • ______SQUARE FEET/200 =______AIRMOVERS
  • -A COMPLEX LOSS NEEDS A DRI-EAZ AIRMOVER EVERY 60 SQUARE FEET. BE SURE TO HAVE AT LEAST ONE PER AREA
  • ______SQUARE FEET/60 = ______AIRMOVER
  • DETERMINE HOW MANY DRI-EAZ DEHUMIDIFIERS ARE NEED FOR YOUR LOSS:
  • -MULTIPLY THE SQUARE FOOTAGE OF THE WET AREA BY THE HEIGHT OF THE CEILING; THIS IS THE VOLUME OF AIR THAT MUST BE DRIED.
  • -DETERMINE AHAM PINTS* OF DEHUMIDIFICATION ARE NEEDED:
  • -A BASIC LOSS:
  • ______CUBIC FEET/100=_________AHAM PINTS
  • -A COMPLEX LOSS:
  • ______CUBIC FEET/50=_______AHAM PINTS
  • -LOOK AT THE DEHUMIDIFIERS AVAILABLE AND SEE HOW MANY IT WILL TAKE TO MATCH THIS MANY AHMA PINTS. YOU NEED AT LEAST AS MANY PINTS AS THE PREVIOUS STEP CALLED FOR. SEE REVERSE SIDE OF THIS SHEET FOR SPECIFICATION OF DEHUMIDIFERS. THIS CALCULATIO ASSUMES DRI-EAZ LOW GRAIN REFRIDERANT DEHUMIDIFERS ARE BEING USED. IF CONVENTIONAL DEHUMIDIFERS ARE USED, INCREASE DEHUMIDIFERS BY 20 PERCENT(MULTIPLY BY 1.2)
  • SET UP EQUIPMENT IN YOUR STRUCTURE:
  • -PLACE DEHUMIDIFERS CENTRALLY IN TH WET AREA. COMPLETELY UNWRAP THE DRAIN HOSE AND SECURELY INSERT INTO A DRAIN. DO NOT PLACE INTO A BUCKET-IT WILL OVER FLOW. IF TEMPERTURES ARE ABOVE FREEZING OUTSIDE, THE DRAIN CAN BE DIRECTED UP AND OUT A BASEMENT WINDOW. BE SURE THAT THE DRAIN HOSE IS NOT CRIMPED.
  • -PLACE AIRMOVERS NEAR THE WALLS IN THE AFFECTED AREA. MAKE SURE THAT ALL THE AIRMOVER ARE POINTING THE SAME DIRECTION.
  • SEE EXAMPLE DIAGRAM ON THE REVERSE OF THIS SHEET.
  • -TRY TO MAINTAIN A TEMPERTURE ABOVE 70 DEGREES AND KEEP THE WINDOW AND DOORS CLOSED DURING DRYING.
  • CHECK WET AREAS DAILY
  • -IF WET AREAS ARE NOT MAKING DRYING PROCESS: MOVE AIRMOVERS CLOSER, OR BLOW DRY AIRFROM THE DEHUMMIDIFERS MORE DIRECTLY ON THE WET AREA
  • -IF WET AREAS ARE NOT MAKING DRYING PROGRESS AFTER 48 HOUS, GET HELP FROM PROFESSIONAL WATER DAMAGE RESTORATION COMPANY.
  • -WHEN WET AREAS BECOME DRY, EQUIPMENT CAN BE REMOVED. THIS MAY TAKE ANYWHERE FROM 2 TO 4 DAY.
  • -IF AFTER 3 TO 4 DAYS THE WET AREAS ARE NOT DRY OR MAKING SIGNFICANT PROGRESS, GET HELP FROM A FROFESSIONAL RESTORATION COMPANY